− | Will the unit still work without the {{R1}}?<ref>From the Product FAQs: [http:// | + | Will the unit still work without the {{R1}}?<ref>From the Product FAQs: [http://toonz.ca/bose/wiki/index.php?title=L1%E2%84%A2_Model_I/FAQ#Will_the_unit_still_work_without_the_R1_remote_control.3F Will the unit still work without the R1 remote control?]</ref> |
+ | |||
+ | The {{PS1}} continuously senses activity at all [[Presets/Model I and Classic|preset]] selectors and what is connected at the [[Template:PS1 Connections Interactive|input/output jacks]]. In general, it is not recommended to operate without the {{R1}} connected. The {{PS1}} can however function without the {{R1}}. If you power the {{PS1}} on without the {{R1}} connected, it will operate as if the {{R1}} was connected and at a fixed setting of 12 o'clock (center position) on all the control knobs. Alternatively, if the unit is powered on with the {{R1}} first connected and the user then disconnects the {{R1}}, it will retain the last settings of the {{R1}} before you disconnected it. This is helpful in the case where sharing may be necessary. | ||
+ | |||
− | |||
==== Full Power ==== | ==== Full Power ==== | ||
− | If you do proper gain staging, the system will get to full output with all knobs at 12 o'clock. Since proper gain staging is not trivial, we provide the extra gain to take up the slack if the input is not quite hot enough.<ref>Hilmar-at-Bose [http://bose.infopop.cc/eve/forums/a/tpc/f/867107664/m/8491032313?r=6271073313#6271073313 | + | {{:Full Power at 12:00 on Master Level}} |
+ | |||
+ | <includeonly> | ||
+ | -- [http://bose.infopop.cc/eve/forums/a/tpc/f/867107664/m/8491032313?r=6271073313#6271073313 Hilmar talks about full power the discussion board] | ||
+ | </includeonly> | ||
+ | <!-- | ||
+ | If you do proper gain staging, the system will get to full output with all knobs at 12 o'clock. Since proper gain staging is not trivial, we provide the extra gain to take up the slack if the input is not quite hot enough.<ref>Hilmar-at-Bose [http://bose.infopop.cc/eve/forums/a/tpc/f/867107664/m/8491032313?r=6271073313#6271073313 Hilmar talks about full power the discussion board]</ref> | ||
+ | --> | ||
+ | |||
+ | <noinclude> | ||
+ | ---- | ||
<references/> | <references/> | ||
− | |||
[[category:L1™ System]] | [[category:L1™ System]] | ||
[[category:PS1 Powerstand]] | [[category:PS1 Powerstand]] |
Latest revision as of 17:08, 29 December 2007
R1 Remote Recommended
Will the unit still work without the R1 Remote?[1]
The PS1 Power Stand (Classic) / Model I continuously senses activity at all preset selectors and what is connected at the input/output jacks. In general, it is not recommended to operate without the R1 Remote connected. The PS1 Power Stand (Classic) / Model I can however function without the R1 Remote. If you power the PS1 Power Stand (Classic) / Model I on without the R1 Remote connected, it will operate as if the R1 Remote was connected and at a fixed setting of 12 o'clock (center position) on all the control knobs. Alternatively, if the unit is powered on with the R1 Remote first connected and the user then disconnects the R1 Remote, it will retain the last settings of the R1 Remote before you disconnected it. This is helpful in the case where sharing may be necessary.
Full Power
Even without the R1 Remote control the system can get to full output if the input trims are carefully set.
If you do proper gain staging, the system will get to full output with all knobs at 12 o'clock. Since proper gain staging is not trivial, we provide the extra gain to take up the slack if the input is not quite hot enough.[2]
- ↑ From the Product FAQs: Will the unit still work without the R1 remote control?
- ↑ Hilmar-at-Bose quote from the discussion board